5.1. Specifications
|
Separate parameters are specified also in the text of the Head and in case of obligation of their performance are highlighted in bold type. |
Cooling system
Characteristic |
Value |
Volume of cooling liquid
|
See the Head Routine maintenance
|
Settlement pressure of a cover of a radiator, kgf/cm 2
|
|
0.6 — 0.98 |
|
9 — 14 |
Temperature of opening of the thermostat, °C
|
82 |
Valve stroke of the thermostat, mm
|
10 (at 95 °C) |
Air conditioning system
Characteristic |
Value |
Type of the K/V compressor
|
Calsonic V6 is 6-cylinder |
Coolant type
|
R-134a |
Volume of coolant, ml
|
633 — 738 |
Type of refrigerator oil
|
"S" (No. KLH00-PAGS0) |
The volume of the refrigerator oil which is filled in during the changing of components, ml |
|
To fill in in the quantity equal to amount of the merged oil |
|
75 |
|
75 |
|
6 |
|
204 |
Working pressure in system at a temperature of 30 °C and relative humidity of 50 — 70% (to check not less than 10 minutes later after start of system)
|
- Low pressure path, kgf/cm 2
|
2.0 — 2.8 |
- High-pressure path, kgf/cm 2
|
14.5 — 19.2 |
Effort of a tension of a belt of the drive of the K/V compressor |
- Size of a deflection of a new belt, mm
|
9.0 — 10.0 |
- The size of a deflection of the belt which was in the use, mm
|
- Models till 1999 of the issue.
|
9.0 — 11.0 |
- Models since 2000 of the issue.
|
10.5 — 11.5 |
Location of service valves of the compressor |
|
In the line of a low pressure between the evaporator and the compressor |
|
In the line of a high pressure between the compressor and the condenser |
Productivity of the K/V system
Temperature of external air, °C |
Temperature on leaving the system, °C |
At relative humidity of 50 — 60% |
25 |
6 — 9 |
30 |
10 — 13.6 |
35 |
15.2 — 19.5 |
40 |
22.5 — 27.1 |
At relative humidity of 60 — 70% |
25 |
9 — 12.2 |
30 |
13.6 — 17.2 |
35 |
19.5 — 23.7 |
40 |
27.1 — 32.3 |
Temperature and pressure head characteristics of system
Temperature of external air, °C (at relative humidity of 50 — 70%)
|
Pressure in a high-pressure path, kgf/cm 2
|
Pressure in a low pressure path, kgf/cm 2
|
25 |
12.5 — 16.7
|
1.8 — 2.6
|
30 |
14.5 — 19.2
|
2.0 — 2.8
|
35 |
16.9 — 22.3
|
2.4 — 3.2
|
40 |
19.6 — 25.5
|
29. — 3.8
|
Condition of the double-thread switch
Pressure, kgf/cm 2
|
Condition of system |
Conductivity between plugs 1 and 2 |
Low pressure path |
Lowering to 1.6 — 2.0
|
Off.
|
No
|
Raising to 1.6 — 2.0
|
Incl.
|
Takes place
|
High-pressure path |
Lowering to 19 — 23 |
Incl.
|
Takes place
|
Raising to 19 — 23 |
Off. |
No
|
|
|